zuUlimi

160kW Energy Storage Inverter Ye-BESS

160kW Energy Storage Inverter Ye-BESS
Imininingwane:
I-160kW Energy Storage Inverter ye-BESS isekela amasistimu ebhethri-enamandla kagesi aphezulu, ukuthunyelwa kwamandla asheshayo, kanye negridi eguquguqukayo-isebenza{3}}yodwa{3}}yodwa yephrojekthi edinga isitoreji kanye ne-microgrid.

●Kufika kokungu-1500V Okuphezulu{1}}Okokufaka i-Voltage BESS
● Ukuvikelwa kwe-IP66 Kwezindawo Ezinokhahlo
● Ngaphansi noma kulingana ne-15ms Fast Power Dispatch Response
●1.5× Amandla okulayisha ngokweqile amasekhondi angu-10
●I-VSG-I-Ready Grid kanye nokusebenza kwe-Microgrid
Thumela ukuPhenya
Landa
Incazelo
I-Parameters yobuchwepheshe

Isiguquli Sesitoreji Samandla esingu-160kW se-BESS

I-160kW Energy Storage Inverter ye-BESS yakhelwe-isitoreji sebhethri le-voltage ephezulu, i-microgrid, kanye negridi-amaphrojekthi osekelo adinga ukuguqulwa kwamandla okuzinzile nokulawulwa kwesistimu esabelayo.

Isekela kokubili insiza-esebenzisanayo futhi{1}}ukusebenza yodwa, iyenze ifaneleke ezentengiselwano ne-BESS yezimboni, amasistimu kagesi eziqhingini, kanye nokuhlanganiswa kwamandla avuselelekayo. Idizayini eqondisiwe yephrojekthi-yayo isiza abahlanganisi besistimu bakhe izixazululo zesitoreji ezithembekile zezimo zokusebenza ezinzima kanye nezidingo zamandla ezishintshayo.

Xhumana nathi

160kW Energy Storage Inverter For BESS

 

Izici Eziyinhloko

 

Yakhelwe-i-BESS ye-voltage ephezulu, izindawo ezidinga kakhulu, nokusebenza kwe-microgrid esabelayo.

-I-Voltage Battery Integration Ephezulu

Isekela ububanzi bevoltheji ye-DC efika ku-1500V, inika amandla ukuxhumeka ngamasistimu ebhethri{1}}enamandla kagesi aphezulu kumaphrojekthi wezohwebo, izimboni, kanye ne-microgrid BESS.

 

I-Flexible Grid kanye ne-Stand Alone Operation

Isebenza kuzo zombili izinsiza-ezimodini ezisebenzisanayo nezizimele{1}}zodwa, ihlinzeka ngokuguquguquka okukhulu kwegridi{2}}yesitoreji esixhunyiwe, amandla ayisipele, namasistimu anamandla azimele.

Fast Power Dispatch Response

Isikhathi sokuphendula sokuthunyelwa kwamandla Esingaphansi noma esilingana no-15ms sisiza isiguquli esinezinhlangothi ezimbili sisabele ngokushesha ekushintsheni kwezimo zomthwalo negridi.

Amandla Okulayishwa Kakhulu-Esikhathi Esifushane

Isekela izikhathi ezingu-1.5 zokulayisha ngokweqile ngamasekhondi angu-10, inikeze amandla engeziwe phakathi nokwenyuka komthwalo okungazelelwe kanye{2}}neziqongo ezimfushane zesidingo sesikhathi.

 

IP66 Ukuvikelwa Kwangaphandle

Indawo ebiyelwe ye-IP66, −25℃kuya ku-60℃ibanga lokusebenza, kanye nezinketho zokufaka eziningi zisekela ukuthunyelwa kwangaphandle eziqhingini, ogwadule, nakwezinye izindawo ezinzima.

I-VSG ne-Microgrid Support

Ubuchwepheshe be-VSG busekela izinhlelo zokusebenza ze-microgrid, kuyilapho ukusebenzisana ne-FFR, i-FCR, ne-FCAS kunweba indima yayo kugridi-yokusekela kanye nemvamisa{1}}amaphrojekthi okuphendula.

Ukucaciswa

  I-Utility-Imodi yokusebenzisana Imodi yokuma wedwa-
Amapharamitha kagesi  
Amandla Okuzisholo 160 kVA
I-AC Voltage

EX: 400 (-15%~15%) Vac

NA: 480 (-15%~15%) Vac

EX: 400 (-10%~15%) Vac

NA: 480 (-10%~15%) Vac

I-DC Voltage Range EX: 720 V~1500 V, >I-1200 V ifinyelela ku-90%
NA: 850 V~1500 V, >I-1200 V ifinyelela ku-90%
I-AC Yamanje

EX: 230A

Inombolo yepholisi: 192A

DC Yamanje

EX:222A

Inombolo yepholisi: 188A

Ukuxhumana kwe-AC 3P4W/3P3W 3P4W
Imvamisa ye-AC 50/60 (-2.5~2.5) Hz
I-THDI Ngaphansi noma kulingana no-3%
I-Voltage Ripple Coefficient Ngaphansi noma kulingana no-1%
I-AC PF -1~1
I-AC Overload Amandla 176 kVA (izikhathi ezingu-1.1 ubude-isikhathi / izikhathi ezingu-1.5 ngokulayisha ngokweqile okungu-10s)
Amapharamitha wesistimu  
Ukusebenza Okukhulu 98.5% (Umthombo osizayo wangaphandle)
Ubukhulu

893 mm × 290 mm × 1080 mm (ububanzi × ukuphakama × ukujula)

893 mm × 290 mm × 950 mm (Akukho Lug)

Umsindo <80 dB @ 1 m
Indawo ebiyelwe P66
Operation Temperature -25 °C ~ 60°C (>50℃derating)
Ukupholisa Ukupholisa umoya ngempoqo
Operation Humidity 0~100% (akukho ukufingqa)
Operation Altitude 3000 m (>3000 m ubude)
Indlela Yokufaka Ukufakwa okukhweziwe okuphansi / okuqondile / odongeni{0}}
Isitifiketi EN50549-1 / EN50549-2 / UL1741 & IEEE1547 / IEC62477 / IEC61000 / FCC
Ukuxhumana  
ukuxhumana RS 485, Ethernet, CAN
Iphrothokholi Yezokuxhumana I-Modbus TCP/RTU, CAN2.0
 
 Lokho Elikuxazululayo

Yakhelwe Ngokuzungeza Imibuzo Yokuhlanganisa Onjiniyela Be-BESS Kudingeka Bayiphendule

 

Ngaphezu kwemikhiqizo evamile esivele siyikhiqiza.

Xhuma-Amasistimu Ebhethri Anamandla Kagesi Aphezulu Ngaphandle Kokuphoqa Iwindi Elincane Le-DC

Ukucushwa kwaseYurophu kusebenza kusuka ku-720–1500V DC kanye nokucushwa kwaseNyakatho Melika kusuka ku-850–1500V DC. Lokhu kunikeza abahlanganisi imvilophu ye-voltage ecacile yokufanisa iyunithi yezinhlamvu zebhethri{5}}ezinamandla kagesi aphezulu kuyilapho kubalwa isimo esishicilelwe sokwehliswa ngaphezu kuka-1200V.

Phendula Ngokushesha ku-Dispatch and Layisha Izinguquko

Impendulo engaphansi noma elingana no-15ms yokuthunyelwa kwamandla isiza isiguquli ukuba sisabele ngokushesha lapho i-EMS ishintsha imiyalo yokushaja noma yokukhipha noma lapho izimo zokusebenza zishintsha. Lokhu kuwusizo kumaphrojekthi we-BESS lapho isivinini sibalulekile khona ekulawuleni amandla asebenzayo kanye -nemisebenzi yokuphendula imvamisa.

Bamba Iziqongo Zamandla Zesikhashana Ngaphandle Kokuvala Ngokushesha

I-inverter isekela umthamo wokulayisha ngokweqile we-176 kVA AC, okuhlanganisa ukusebenza kwethemu engu-1.1 ubude{2}}nokulayisha ngokweqile izikhathi ezingu-1.5 imizuzwana engu-10. Leyo ndlu yekhanda yesikhathi esifushane{6}engeziwe iwusizo lapho isayithi lithola ukukhuphuka komthwalo okuzumayo noma isidingo esidlulayo esingaphezu kwamandla avamile.

Sebenzisa i-One Inverter for Utility-I-Interactive noma I-Stand-Umsebenzi Wedwa

Iyunithi isekela kokubili ukusetshenziswa{0}}izindlela ezisebenzisanayo nezizimele{1}}zodwa. Ngakho-ke abahlanganisi bangasebenzisa umndeni ofanayo womkhiqizo ukuze benze igridi-isitoreji sebhethri esixhunyiwe noma amasistimu okumele anakekele ibhasi le-AC elizimele, ngaphansi kokuvikelwa kokugcina nokulawula izakhiwo.

Sekela i-VSG Nemvamisa-Izicelo Zokuphendula

Ubuchwepheshe be-VSG busekela izinhlelo zokusebenza ezidinga i-voltage elawulwayo nokuziphatha kwefrikhwensi, kuyilapho ukusebenzisana ne-FFR, FCR kanye ne-FCAS kunweba indima ye-inverter kumaphrojekthi wosekelo wegridi-. Izidingo zegridi kufanele zihlale zibhekwa ngokuqhathanisa nendawo yephrojekthi kanye nemibhalo esebenzayo yokuthobela imithetho.

Sebenzisa Kuzo zonke Imibandela Yesayithi Efunwa Ngayo

Ukuvikelwa kwe-IP66 okushicilelwe, {1}ukupholisa komoya okuphoqelelwe, −25℃kuya ku-60℃ububanzi bokusebenza, 0–100% non{6}}ibanga lomswakamo ongafinyeleliyo kanye nokuphakama okusebenzayo okungu-3000m kunikeza izihlanganisi imikhawulo ecacile yemvelo yokwakheka kwesayithi kanye nezibalo ezehlisayo.

Consulting Engineer

 

Ukuhlanganiswa Kwesistimu

Lapho I-Inverter Yesitoreji Samandla angu-160kW Ihlala ku-BESS

Ngo ejwayelekileukwakhiwa kwesistimu yokugcina amandla ebhethri, isiguquli silawula ukuguqulwa phakathi-kohlangothi lwebhethri ye-DC ephezulu kanye nesistimu ye-AC. I-BMS ivikela futhi igade ibhethri, kuyilapho i-EMS noma isilawuli sesayithi singakwazi ukuxhumana ne-inverter nge-RS485, Ethernet noma i-CAN sisebenzisa i-Modbus TCP/RTU noma i-CAN2.0.

Ibhethri-I-Voltge Ephezulu

1

>>

Ukuvikelwa kwe-DC

2

>>

160kW Energy Storage Inverter

3

>>

Ibhasi le-AC / Transformer

4

>>

Igridi noma Umthwalo Wesayithi

5

Ngaphambi kokusebenzisa, qinisekisa amandla ebhethri kanye nemikhawulo yamanje, izintambo ze-AC, imvamisa yegridi, imephu yokuxhumana, ukuxhumana kokuvikela kanye nendawoukuhambisana kwegridi. Kumaqembu adinga incazelo ebanzi yendima yesiguquli, ukubuka konke kwe-Polinoveluhlelo lokuguqula amandla (PCS)ihlanganisa-umsebenzi wezinga lesistimu.

 

I-System Integration Consulting

 

 

Lapho Le Inverter engu-160kW Yengeza Inani Kakhulu

 

Umkhiqizo ubekwe kahle kakhulu endaweni yokuguqulwa{0}}kwebhethri ye-voltage enamandla namandla alawulekayo asheshayo-hhayi njenge-generic hybrid inverter. Lezi izinhlelo zokusebenza eziqondana kakhulu nezici zayo zikagesi nokulawula ezishicilelwe.

I-BESS yezohwebo nezimboni

Emafekthri, iziza zezimboni nezindawo zentengiso, isiguquli esingu-160kW singalawula ukushajwa kwebhethri futhi sikhiphe phakathi nesidingo sesayithi, imiyalo yokuphatha amandla kanye nezidingo zokulondoloza. Izinketho zayo ze-400V/480V AC zisiza izihlanganisi ukufanisa-amasistimu wamandla ezigaba ezintathu ezivamile kuzo zonke izimakethe ezihlukene.

Isitoreji Samandla Avuselelekayo Nokwesekwa Kwegridi

I-inverter ingasekela amaphrojekthi okugcina amandla avuselelekayo lapho amandla ebhethri kufanele aphendule kugridi noma imiyalo ye-EMS. Okungaphansi noma okulingana nokuthunyelwa kwempendulo engu-15ms, ububanzi besici samandla alungisekayo kanye namandla ahlobene e-VSG-abalulekile ikakhulukazi uma i-BESS ibamba iqhaza ekulawuleni amandla asebenzayo noma{3}}izinsizakalo zokuphendula imvamisa.

I-Stand Alone & Islanded Power Systems

Umsebenzi wokuzimela-wodwa uvumela isiguquli ukuthi sinikeze amaphrojekthi adinga ukunikezwa kwe-AC okuzimele kunokuthembela kugridi yokusetshenziswayo. Izintambo ze-AC ezishiwo, amandla okulayisha ngokweqile kanye nemikhawulo yendawo kufanele ifaniswe nephrofayela yangempela yokulayisha kanye nezimo zesayithi ngaphambi kokuthunyelwa.

Imininingwane Emihlanu Eqinisekisiwe Mayelana Nesiguquli Sesitoreji Samandla se-BESS

Okokufaka Kwephrojekthi Kungani Ibalulekile Kule Model engu-160kW
Iwindi le-Battery Voltage Qinisekisa ukuthi ibhethri lihlala phakathi kuka-720–1500V DC ekucushweni kwe-EX noma 850–1500V DC ekucushweni kwe-NA, okuhlanganisa nokuncishiswa okushicilelwe okungaphezulu kuka-1200V.
Isistimu ye-AC Qinisekisa ukuthi iphrojekthi isebenzisa i-400 Vac noma i-480 Vac nokuthi izintambo ezidingekayo ziyi-3P4W noma i-3P3W.
Imodi yokusebenza Chaza ukuthi i-inverter izosebenzisa usizo-esebenzisanayo,{1}}yodwa, noma ishintshe phakathi kwamasu okusebenza ngaphansi kwesilawuli sangaphandle.
Ukulawula Nokuxhumana Qinisekisa ukuhlanganiswa kwe-EMS/BMS nge-RS485, Ethernet noma i-CAN futhi uqinisekise i-Modbus TCP/RTU edingekayo noma i-CAN2.0 yokumepha idatha.
Izimfuneko Zesayithi Negridi Hlola izinga lokushisa le-ambient, ukuphakama, okulindelwe kwendawo ebiyelwe, imvamisa, isitifiketi kanye nanoma iyiphi iphrojekthi-igridi ethize{1}}izidingo zosekelo ngaphambi kokukhishwa kokukhiqizwa.

 

Imibuzo Evame Ukubuzwa Onjiniyela NgeModel engu-160kW

Q: Iyiphi i-voltage yebhethri esekelwa i-inverter yokugcina amandla engu-160kW?

A: Ibanga lamandla kagesi e-DC elishicilelwe lingu-720–1500V ekucushweni kwe-EX kanye no-850–1500V ekucushweni kwe-NA. Ngaphezulu kuka-1200V, ukucaciswa okukhona kuthi kwehlela ku-90%. I-voltage yangempela yokusebenza yebhethri kuyo yonke i-SOC nezinga lokushisa kufanele kubhekwe kulobu bubanzi.

Q: Uyini umehluko phakathi kokucushwa kwaseYurophu naseNyakatho Melika?

A: Inguqulo ye-EX icaciswe cishe ku-400 Vac futhi isebenzisa ububanzi obungu-720–1500V DC, kuyilapho inguqulo ye-NA icaciswa cishe ku-480 Vac futhi isebenzisa ububanzi obungu-850–1500V DC. Amanani amanje e-AC ne-DC nawo ayahluka, ngakho-ke ukumiswa kwesifunda okulungile kufanele kukhethwe phakathi nokuklanywa kwesistimu.

Umbuzo: Ingabe i-inverter ingasebenza ngaphandle kwegridi yokusetshenziswa?

A: Yebo. Ukucaciswa komkhiqizo kwamanje kuhlanganisa kokubili ukusetshenziswa{1}izindlela zokusebenzisana nezizimele{2}}zodwa. Uxhumano lwe-AC oluzimele-lodwa lufakwe kuhlu njenge-3P4W, kuyilapho insiza{7}}i-interactive operation isekela i-3P4W/3P3W. Ukuvikelwa kwesistimu yokugcina kanye nengqondo yokulawula kufanele kuhlanganiswe nomklamo ophelele we-BESS.

Q: Ngabe i-inverter iphendula ngokushesha kangakanani emiyalweni yamandla?

A: Impendulo yokuthunyelwa kwamandla eshicilelwe Ingaphansi noma ilingana no-15ms. Leli khono lokuphendula libalulekile uma i-BESS idinga ukulandela imiyalo ye-EMS esheshayo noma ibambe iqhaza kugridi-yokusekela kanye nemvamisa{3}}izinhlelo zokusebenza zokuphendula.

Q: Yiziphi izindlela zokuxhumana ezikhona?

A: Idatha yomkhiqizo ekhona yenza uhlu lwe-RS485, i-Ethernet kanye ne-CAN yokuxhumana, ne-Modbus TCP/RTU ne-CAN2.0 protocol. Ngesikhathi sokuhlanganiswa kwephrojekthi, qinisekisa imephu yerejista edingekayo, ingqondo yokuxhumana ye-BMS/EMS kanye nezibopho zomlawuli.

Umbuzo: Yimaphi amadokhumenti okusebenza okufanele ngiwaqinisekise ngaphambi kokuthenga?

A: Okungenani, qinisekisa imininingwane yokugcina yemodeli, imininingwane yezintambo kanye nokufaka, imibhalo yokuxhumana kanye namafayela ezitifiketi asebenzayo.

 

modular-1

Qinisekisa i-Inverter engu-160kW ngokumelene nebhethri lakho kanye nesistimu ye-AC

Thumela i-voltage yokusebenza kwebhethri lakho, umthamo we-BESS, i-voltage ye-AC, imakethe yendawo, insiza-esebenzayo noma{1}}imfuneko yokuma wedwa, kanye nephrothokholi yokuxhumana edingekayo. I-Polinovel ingasebenzisa la ma-inputs ukuze iqinisekise ukuthi lesi siguquli sesitoreji samandla esingu-160kW sifana nezidingo zikagesi nokulawula zephrojekthi yakho.

 

 

 

 

Amashadi ashisayo: I-inverter yokugcina amandla engu-160kW, i-inverter engu-160kW BESS, i-inverter yokugcina amandla kagesi aphezulu, i-inverter yokugcina amandla engu-1500V, i-inverter yokugcina engu-160kVA

Thumela ukuPhenya
Amandla Ahlakaniphile, Ukusebenza Okuqinile.

I-Polinovel iletha izixazululo eziphezulu-zokusebenza kwesitoreji samandla ukuze kuqiniswe ukusebenza kwakho ngokumelene nokuphazanyiswa kukagesi, ukwehlisa izindleko zikagesi ngokuphathwa okuphezulu okuhlakaniphile, nokuletha amandla aqhubekayo,{1}}alungile esikhathini esizayo.